Blasters Multimeter Model 109
|
|
Modified for the blasting industry. The 109 Blasting Multimeter is designed for safe, precise circuit measurement when using electric detonators. It has a built-in current limiting circuit with current output less than 0.004 amps (4 miliamperes).
FEATURES
|
|
DC Voltage
|
200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1500 V
|
AC Voltage
|
200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1000 V
|
Current
|
AC/DC 200.0 µA, 2.000 mA, 20.00 mA, 200.0 mA, 2 A
|
Resistance
|
200.0 O, 2.000 kO, 20.00 kO, 200.0 kO, 2.000 MO, 20.00 MO
|
Specifications
|
DC Volts range:
|
200 mV, 2 V, 20 V, 200 V, 1500 V
|
DC Volts resolution:
|
0.1 mV
|
DC Volts accuracy:
|
All ranges ±(0.1 % rdg+2 dgts)
|
DC Volts input impedance:
|
10 MO
|
DC Volts OL protection:
|
>1500 V DC/1000 V AC rms
|
DC Volts transient protection:
|
>12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV
|
AC Volts (45 Hz to 2 kHz) ranges:
|
200 mV, 2 V, 20 V, 200 V, 1000 V
|
AC Volts (45 Hz to 2 kHz) resolution:
|
0.1 mV
|
AC Volts (45 Hz to 2 kHz) accuracy:
|
200 mV to 200 V (45-500 Hz) ±(0.8 % rdg+4 dgts),
|
AC Volts (45 Hz to 2 kHz) accuracy:
|
200 mV to 200 V (500 Hz-2 kHz) ±(1.5 % rdg+5 dgts)
|
AC Volts (45 Hz to 2 kHz) accuracy:
|
1000 V (50-60 Hz) ±(0.8 % rdg+4 dgts)
|
AC Volts (45 Hz to 2 kHz) accuracy:
|
1000 V (60-500 Hz) ±(1.5 % rdg+5 dgts)
|
AC Volts (45 Hz to 2 kHz) input impedance:
|
10 MO
|
AC Volts (45 Hz to 2 kHz) OL protection:
|
1500 V DC/1000 V AC rms
|
AC Volts (45 Hz to 2 kHz) transient protection:
|
12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV.
|
DC Current range:
|
200 µA, 2 mA, 20 mA, 200 mA, 2 A
|
DC Current resolution:
|
0.1 µA
|
DC Current accuracy:
|
200 µA to 20 mA ±(0.5 % rdg+2 dgts)
|
DC Current accuracy:
|
200 mA to 2 A ±(1.0 % rdg+2 dgts)
|
|
|
|